<?xml version="1.0" encoding="ISO-8859-1"?>

<rdf:RDF
 xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
 xmlns="http://purl.org/rss/1.0/"
 xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/"
 xmlns:dc="http://purl.org/dc/elements/1.1/"
 xmlns:syn="http://purl.org/rss/1.0/modules/syndication/"
 xmlns:prism="http://purl.org/rss/1.0/modules/prism/"
 xmlns:admin="http://webns.net/mvcb/"
>

<channel rdf:about="http://www.ptjournal.org">
<title>Physical Therapy Technical Reports</title>
<link>http://www.ptjournal.org</link>
<description>Physical Therapy RSS feed -- recent Technical Reports articles</description>
<prism:eIssn>1538-6724</prism:eIssn>
<prism:publicationName>Physical Therapy</prism:publicationName>
<prism:issn>0031-9023</prism:issn>
<items>
 <rdf:Seq>
  <rdf:li rdf:resource="http://www.ptjournal.org/cgi/content/short/88/1/50?rss=1" />
  <rdf:li rdf:resource="http://www.ptjournal.org/cgi/content/short/88/1/58?rss=1" />
  <rdf:li rdf:resource="http://www.ptjournal.org/cgi/content/short/88/1/61?rss=1" />
 </rdf:Seq>
</items>
<image rdf:resource="http://www.ptjournal.org/icons/banner/title.gif" />
</channel>

<image rdf:about="http://www.ptjournal.org/icons/banner/title.gif">
<title>Physical Therapy</title>
<url>http://www.ptjournal.org/icons/banner/title.gif</url>
<link>http://www.ptjournal.org</link>
</image>

<item rdf:about="http://www.ptjournal.org/cgi/content/short/88/1/50?rss=1">
<title><![CDATA[Variability in Effective Radiating Area at 1 MHz Affects Ultrasound Treatment Intensity]]></title>
<link>http://www.ptjournal.org/cgi/content/short/88/1/50?rss=1</link>
<description><![CDATA[
<P><B>Background and Purpose:</B> Previous research has indicated that not all ultrasound transducers heat at equal rates; however, the cause of this disparity is unclear. Variability in spatial average intensity (SAI) has been implicated in this disparity at 3 MHz. This variability has not been explored at 1 MHz.</P>
<P><B>Methods:</B> Sixty-six 5-cm<SUP>2</SUP> ultrasound transducers were purchased from 6 different manufacturers. Transducers were calibrated and assessed for effective radiating area (ERA), total output power, and SAI using standardized measurement techniques.</P>
<P><B>Results:</B> Total output power values fell within US Food and Drug Administration guidelines, but there were large variations in ERA. The resulting SAI values showed large deviations (&ndash;43% to +61%) from the digitally displayed value. Intra-manufacturer SAI values varied up to 53%.</P>
<P><B>Discussion and Conclusion:</B> Spatial average intensity can vary largely from the values displayed on these ultrasound generators; in a calibrated cohort, this difference is primarily attributable to differences in measured ERA. Patterns of SAI variability within the manufacturer at 1 MHz do not follow previous reports of variability at 3 MHz.</P>
]]></description>
<dc:creator><![CDATA[Straub, S. J, Johns, L. D, Howard, S. M]]></dc:creator>
<dc:date>2007-12-31</dc:date>
<dc:identifier>info:doi/10.2522/ptj.20060358</dc:identifier>
<dc:title><![CDATA[Variability in Effective Radiating Area at 1 MHz Affects Ultrasound Treatment Intensity]]></dc:title>
<dc:publisher>American Physical Therapy Association</dc:publisher>
<prism:number>1</prism:number>
<prism:volume>88</prism:volume>
<prism:endingPage>57</prism:endingPage>
<prism:publicationDate>2008-01-01</prism:publicationDate>
<prism:startingPage>50</prism:startingPage>
<prism:section>Technical Reports</prism:section>
</item>

<item rdf:about="http://www.ptjournal.org/cgi/content/short/88/1/58?rss=1">
<title><![CDATA[Invited Commentary]]></title>
<link>http://www.ptjournal.org/cgi/content/short/88/1/58?rss=1</link>
<description><![CDATA[]]></description>
<dc:creator><![CDATA[Robertson, V. J]]></dc:creator>
<dc:date>2007-12-31</dc:date>
<dc:identifier>info:doi/10.2522/ptj.20060358.ic</dc:identifier>
<dc:title><![CDATA[Invited Commentary]]></dc:title>
<dc:publisher>American Physical Therapy Association</dc:publisher>
<prism:number>1</prism:number>
<prism:volume>88</prism:volume>
<prism:endingPage>61</prism:endingPage>
<prism:publicationDate>2008-01-01</prism:publicationDate>
<prism:startingPage>58</prism:startingPage>
<prism:section>Technical Reports</prism:section>
</item>

<item rdf:about="http://www.ptjournal.org/cgi/content/short/88/1/61?rss=1">
<title><![CDATA[Author Response]]></title>
<link>http://www.ptjournal.org/cgi/content/short/88/1/61?rss=1</link>
<description><![CDATA[]]></description>
<dc:creator><![CDATA[Straub, S. J, Johns, L. D, Howard, S. M]]></dc:creator>
<dc:date>2007-12-31</dc:date>
<dc:identifier>info:doi/10.2522/ptj.20060358.ar</dc:identifier>
<dc:title><![CDATA[Author Response]]></dc:title>
<dc:publisher>American Physical Therapy Association</dc:publisher>
<prism:number>1</prism:number>
<prism:volume>88</prism:volume>
<prism:endingPage>62</prism:endingPage>
<prism:publicationDate>2008-01-01</prism:publicationDate>
<prism:startingPage>61</prism:startingPage>
<prism:section>Technical Reports</prism:section>
</item>

</rdf:RDF>