|
|
||||||||
Research Reports |
D Falla, PT, BPhty (Hons), is a doctoral student, Department of Physiotherapy, The University of Queensland, St Lucia, Brisbane, 4072 Queensland, Australia (d.falla{at}shrs.uq.edu.au).
G Jull, PT, PhD, is Associate Professor and Head of Department, Department of Physiotherapy, The University of Queensland
P Dall'Alba, PT, BPhty (Hons), is Research Officer, Department of Physiotherapy, The University of Queensland
A Rainoldi is Physicist and a doctoral student, Centro di Bioingegneria, Dip di Elettronica, Politecnico di Torino, Italy, and Department of Physical Medicine and Rehabilitation, University of Tor Vergata and Fondazione Don Gnocchi, Rome, Italy
R Merletti, PhD, is Engineer, Professor, and Director, Centro di Bioingegneria, Dip di Elettronica, Politecnico di Torino
Address all correspondence to Ms Falla
Submitted November 5, 2002;
Accepted June 2, 2003
| Abstract |
|---|
Key Words: Cervical spine Electromyography Longus capitis muscle Longus colli muscle Neck pain
| Introduction |
|---|
|
|
|---|
The deep cervical flexor (DCF) muscles have been studied using techniques such as computer modeling3,4 histological analyses,5 and imaging studies.1 There have been few attempts, however, at obtaining a direct measure of DCF muscle activity via electromyography (EMG). Inaccessibility of the DCF muscles has been the main limitation, preventing direct measurement. Surface electrodes can be used to measure the superficial cervical muscles; however, their use is restricted when the muscle of interest is deeply positioned, such as the longus colli and longus capitis muscles of the cervical spine. Several decades ago, indwelling, fine-wire electrodes were used to measure these deep muscles.6,7 Both EMG studies were limited to subjects without known impairment or pathology, and, as a result, they provided very little information that could be used in the development of interventions for patients with neck pain. Given the complexity and proximity of nearby structures such as the trachea, carotid artery, vagus nerve, and lymphatics, the technique of fine-wire EMG is extremely difficult and highly invasive and thus unsuitable for wider application.
We developed an approach that allows a direct measure of the DCF muscles to be obtained. The apparatus used in this approach, which was developed by one of the authors (PD), consists of electrode contacts attached to a suction catheter that are placed on the posterior oropharyngeal wall using a nasopharyngeal application. The DCF muscles lie directly posterior to the oropharyngeal wall (Fig. 1). This proximity provides a location to make recordings of the DCF muscles via the mucosal wall, without requiring intramuscular recording techniques.
|
| Method |
|---|
|
|
|---|
=30.7, SD=10.3) participated in this study. Subjects were included if they were free of neck pain at the time of testing, had no past history of orthopedic disorders affecting the neck, and had no history of neurological disorders. Each subject was screened according to exclusion criteria that were based on the contraindications and precautions for the use of Xylocaine spray local anesthetic11,* and for the use of the nasopharyngeal suctioning technique.12 The spray and the suctioning technique are required for the surface EMG measure of the deep cervical flexor muscles.
Instrumentation and Measurements
Myoelectric signals were detected from the DCF muscles on the left side using bipolar electrodes (Fig. 2). The apparatus consisted of custom-made, bipolar, silver wire electrode contacts (dimensions: 2 x 0.6 mm, inter-electrode distance: 10 mm) that were attached to a suction catheter (size 10FG) with a heat-sealed distal end. This apparatus was inserted through the nose to the posterior oropharyngeal wall. Although activity of adjacent muscles may contribute to the signal, we believe this activity was minimized by fixing the electrode to the mucosa with suction pressure of 30 mm Hg through a portal between the 2 electrode contacts and by placing the electrode at the level of the uvula (approximately the level of the C2-3 intervertebral disk), which is the level at which the longus colli muscle has its greatest cross-sectional area.13 Each electrode-tipped catheter was individually packed and sterilized using standard gas sterilization procedures.
|
The electrodes were positioned at one third of the distance from the sternal notch to the mastoid process at the distal end overlying the muscle belly14 following careful skin preparation.15 A strap located around the wrist provided a ground reference. Signals were passed through a 20- to 450-Hz bandwidth filter (40 dB/decade slope on each side), sampled at 2,048 Hz, and amplified (ASE16 16-channel amplifier
). The samples were digi-tized by a 12-bit, analog-to-digital converter (DAQ PCI 6024E-10
) and stored on a disk of a personal computer. To obtain a measurement of EMG signal amplitude, the 1-second maximum root mean square (1sRMS) was calculated for each EMG trace using a custom-designed software program.|| A reference voluntary contraction of CCF and cervical flexion should have reflected the combined actions of the deep and superficial cervical flexor muscles. This was done in the supine position in order to normalize the data. The 1sRMS values obtained during each stage of the CCF test for both the deep and superficial cervical flexor muscles were normalized by expressing them as a percentage of the maximum 1sRMS values obtained during the reference voluntary contraction.
The CCF test consists of 5 incremental movements of increasing CCF ROM.16 Performance is guided by visual feedback from an air-filled pressure sensor# positioned suboccipitally. During the CCF test, subjects were required to perform gentle nodding motions of CCF that progressed in range to increase the pressure by 5 incremental levels, with each increment representing 2 mm Hg. The starting pressure was 22 mm Hg, and the ending pressure was 30 mm Hg. Recording of pressure measurements was made by connecting the pressure bag and pump to a pressure transducer. Electrical signals from the pressure transducer were amplified and relayed to a visual feedback device and to the integrated amplifier, the analog-to-digital converter, and the data storage system.** The visual feedback device consisted of a voltmeter, which was marked in 2-mm Hg increments from 20 mm Hg to 30 mm Hg and which was calibrated to display the pressure in the pressure bag, based on the pressure transducer output. Sampling frequency for pressure measures was 1,000 Hz. The pressure traces were reviewed by the chief investigator at the completion of each trial to ensure that the subjects reached each pressure target and maintained the pressure steady on the target for the duration of recording.
The range of CCF that subjects obtained for each stage of the test was measured from a lateral photograph taken with a digital camera (PowerShot 100 DIGITAL IXUS
) and using custom-designed analytical software for angle measurements (LabVIEW 6.0i
). This method has a high level of reliability.16
Experimental Procedure
Subjects were positioned on a plinth in a supine crook-lying position. The starting position was standardized by placing the craniocervical and cervical spines in a position in which the subjects' forehead and chin were horizontal and in an imaginary line that was parallel to the plinth and extended from the tragus of the ear and bisected the neck longitudinally.16
The pressure biofeedback unit was placed suboccipitally behind the subjects' neck and set to a baseline pressure of 20 mm Hg. Subjects were instructed in how to do CCF, and they practiced the head-nodding action to progressively target (reach the incremental targets) and hold the 5 pressure levels for 10 seconds between 22 mm Hg and 30 mm Hg. Any substitutions such as neck retraction were identified by the chief investigator using visual inspection of subject performance from the lateral side and were discouraged. The combined movement of CCF and cervical flexion (head lift with chin tuck) also was practiced in preparation for the reference voluntary contraction.
The digital camera was positioned on a tripod parallel to the subjects' head and neck region at a distance of 80 cm. Anatomical markers were positioned on the tragus of the ear, the mental protuberance of the mandible, and the lateral aspect of the neck7 cm inferior to the mastoid process16 (Fig. 3). Markers were fixed with double-sided medical tape. An initial photograph was taken of each subject in the starting position, followed by a photograph taken after the subject achieved full range of head nod (CCF) while in the supine position.
|
For the normalization procedure, subjects were instructed to perform the combined movement of CCF and cervical flexion. This movement consisted of a full CCF chin nodding action, followed by cervical flexion to lift the head so that it just cleared the plinth. In an effort to make sure there was correct movement, the investigator observed the motion. This contraction was maintained for 10 seconds and was repeated twice, with a rest period of 30 seconds between contractions. The highest value recorded over the 2 contractions became the reference 1sRMS value, allowing subsequent normalization. Subjects then performed the 5 stages of the CCF test, going from 22 mm Hg to 30 mm Hg and maintaining steady pressure on each target for 10 seconds. For each stage of the test, data collection commenced at the point when the subjects reached the pressure target. A digital image also was recorded at this point. An interval of 30 seconds was given between contractions, during which time an investigator checked each subject's head and neck position to ensure that the subject returned to his or her starting position. On completion of testing, the suction pressure was released and the catheter was removed gently.
Reliability
The reliability of normalized 1sRMS values obtained from the DCF muscles during the 5 stages of the CCF test was examined in 5 subjects (2 men, 3 women) between 22 and 53 years of age (
=32.7, SD=14.3). Each subject repeated the experimental protocol 3 times, 1 day apart over nonconsecutive days, performing the CCF test twice each day. Reliability estimates for the normalized 1sRMS values from the DCF muscles were obtained by evaluating intraclass correlation coefficients (ICCs) and the normalized standard error of the mean (SEM). Previous work examining the reliability of surface EMG measurements has identified the advantages of considering both the ICC and the normalized SEM.18,19 When n measurements are performed on each of m subjects, the n·m values have a mean (µ) and a variance (
2). The normalized SEM (100·
/µ
n·m) gives information about the statistical range of values that µ would have in repeated experiments. A low normalized SEM indicates a reliable estimate of µ (eg, minimal experimental noise). Analysis of variance (ANOVA) provides information about the factors contributing to
2 (days, trials, subjects, measurement conditions) regardless of the actual value of
2. Specifically, ICC is the portion of
2 that is associated with differences among measured individuals and tells us if the variations of the measurements reflect subject-to-subject variations or random experimental noise, both of which are components of reliability. Throughout the text, the variances will be presented as a percentage of the total variance because we believe this increases the usefulness of the results.
Data Management and Statistical Analysis
A measure of the DCF muscles during increasing CCF ROM should demonstrate increasing, but not necessarily linear, EMG amplitude from these muscles with increasing effort. A linear mixed model, fitting subjects as a random effect and with fixed stage effects, was therefore applied to determine whether a relationship existed between the amplitude of muscle activity and the 5 incremental stages of the CCF test. In addition, an analysis of contrasts was conducted using t tests to identify whether there were differences between normalized 1sRMS values for each muscle at each stage of the CCF test and whether there were differences in the EMG amplitude increase for each muscle between successive stages of the CCF test. A value of P<.05 was considered statistically significant. Preliminary analysis identified no difference between sides for the AS muscle (P=.5) and the SCM muscle (P=.8), allowing pooling of the data (N=10).
The range of CCF was calculated by subtracting the angle at full head nod from that in the starting position. The ROM obtained at each stage of the CCF test was then expressed as a percentage relative to the full range of CCF obtained. Pearson correlation coefficients were calculated to examine the relationship between range of upper cervical flexion and normalized 1sRMS from each of the 3 muscles studied (N=10).
| Results |
|---|
|
|
|---|
|
|
Table 2 documents the results of ICC and normalized SEM for normalized 1sRMS values obtained from the DCF muscles. Low values of the within-subject normalized SEM were found for the normalized 1sRMS values for the DCF muscle (6.7%10.3%), providing evidence of high reliability for these variables.
|
| Discussion |
|---|
|
|
|---|
Methodological Considerations
Recording of DCF muscle activity involved an EMG technique for the measurement of muscle activity of the DCF muscles. Further research, however, remains necessary to ensure whether cross talk from other nearby muscles, such as the superficial cervical flexor and submandibular muscles, affect recording. Given the location of the electrode and the small inter-electrode distance incorporated in the electrode design, we are confident that the majority of the signals detected are from the longus colli and longus capitis muscles. The low impedance associated with detection over a mucosal surface and fixation of the electrodes with suction, we believe, further assured quality of the myoelectric signals obtained. Other techniques have been used to record EMG activity through mucosa, such as recordings made from the crural fibers of the diaphragm through the esophageal wall.20 We argue that our setup avoided the reported problems associated with movement of the electrode in that technique by fixation of the electrode with suction. The procedure was well tolerated by all subjects, and no side effects associated with the technique or anesthetic were reported.
The reference voluntary contraction of combined CCF and cervical flexion selected for normalization of EMG amplitude was not a true maximum voluntary contraction. As such, the amplitudes of DCF, SCM, and AS muscle activity cannot be accurately compared. Further studies, we believe, are necessary to investigate the contribution of the deep and superficial cervical flexor muscles during performance of the CCF test.
Reliability
The repeatability of normalized 1sRMS values for the DCF muscles obtained during the 5 stages of the CCF test demonstrate reliability or constancy. As previously documented,18,19,21 when the between-subject variability is comparable or less than the within-subject variability, the degree of repeatability defined by the ICC becomes meaningless. The low values obtained for the between- and within-subject variability for the normalized 1sRMS values for the DCF muscles demonstrate that these variables were estimated with very high repeated-measure precision. However, these low values also show that there was very little variation in the normalized 1sRMS values obtained across subjects and trials, so the measure might not be able to detect different muscle properties among uniform groups (eg, subjects without symptoms). The data, therefore, might be best utilized in providing a reference range for a uniform group of subjects (eg, normative data). Further research is indicated to determine the utility of these measures in demonstrating differences between subjects with and without symptoms.
| Conclusion |
|---|
|
|
|---|
| Footnotes |
|---|
Ethical approval for the study was granted by the Medical Research Ethics Committee of The University of Queensland, Australia.
This study was supported by a University of Queensland Small Grant and partially by the Fondazione CRT and Compagnia di San Paolo di Torino.
* Astra Pharmaceuticals, 50 Otis St, Westborough, MA 01581. ![]()
Myotronics-Noromed Inc, 15425 53rd Ave S, Tukwila, WA 98188. ![]()
Laboratorio di Ingegneria del Sistema Neuromuscolare e della Riabilitazione Motoria, Via Cavalli 22G, Politecnico di Torino, Torino, Italy 10138. ![]()
National Instruments Corp, 11500 N Mopac Expwy, Austin, TX 78759-3504. ![]()
|| The MathWorks Inc, 3 Apple Hill Dr, Natick, MA 01760-2098. ![]()
# Chattanooga Group Inc, 4717 Adams Rd, Hixson, TN 37343. ![]()
** Amlab Technologies, 12 McGill St, Lewisham, New South Wales, Australia, 2049. ![]()

Cannon Australia Pty Ltd, 1 Thomas Holt Dr, North Ryde, New South Wales, Australia, 2113. ![]()
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
B. Cagnie, N. Dickx, I. Peeters, J. Tuytens, E. Achten, D. Cambier, and L. Danneels The use of functional MRI to evaluate cervical flexor activity during different cervical flexion exercises J Appl Physiol, January 1, 2008; 104(1): 230 - 235. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Falla, G. Jull, T. Russell, B. Vicenzino, and P. Hodges Effect of Neck Exercise on Sitting Posture in Patients With Chronic Neck Pain Physical Therapy, April 1, 2007; 87(4): 408 - 417. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. D Harris, D. M Heer, T. C Roy, D. M Santos, J. M Whitman, and R. S Wainner Reliability of a Measurement of Neck Flexor Muscle Endurance Physical Therapy, December 1, 2005; 85(12): 1349 - 1355. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P O'Leary, B. T Vicenzino, and G. A Jull A New Method of Isometric Dynamometry for the Craniocervical Flexor Muscles Physical Therapy, June 1, 2005; 85(6): 556 - 564. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |