PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 79, No. 6, June 1999, pp. 558-566

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, D. J
Right arrow Articles by Voelz, J. T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, D. J
Right arrow Articles by Voelz, J. T
Related Collections
Right arrow Kinesiology/Biomechanics
Right arrow Tests and Measurements
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Technical Reports

Accuracy of Digitization Using Automated and Manual Methods

Daniel J Wilson, Bryan K Smith, J Kyle Gibson, Byung K Choe, Brenda C Gaba and John T Voelz

DJ Wilson, PhD, is Clinical Assistant Professor, Gait Laboratory, Department of Physical Medicine and Rehabilitation–DC 0046.00, Howard A Rusk Rehabilitation Center, University of Missouri–Columbia, One Hospital Dr, Columbia, MO 65212 (USA) (dan_wilson{at}pmr.missouri.edu). Address all correspondence to Dr Wilson
BK Smith, JK Gibson, PT, OCS, BK Choe, BC Gaba, and JT Voelz were graduate students, Department of Health and Exercise Sciences, University of Missouri–Columbia, at the time this study was conducted

Background and Purpose. Computerized 3-dimensional (3-D) motion measurement systems are used by those interested in human motion. The purposes of this study were (1) to determine the limits of accuracy in determining intersegmental angles during pendular motion at varying speeds and (2) to determine changes in accuracy introduced by autodigitization and digitization by experienced manual raters. Methods. Angular speed of a T-shaped pendulum was systematically increased by releasing the pendulum from 4 angles (0° [no movement], 45°, 90°, and 120°). Twelve reference angles calculated from markers placed on the pendulum were estimated over 20 frames for 10 trials at each release position. Results. Mean errors across trials and frames for intersegmental angles reconstructed by a 3-D motion measurement system were within ±1 degree across all release positions. An analysis of variance and a post hocTukey test revealed that the mean error for the autodigitized trials was larger than that for the manually digitized trials. For the autodigitized trials, the static trials (release position=0°) produced less mean error than the trials with movement produced. The ICCs showed a high degree of consistency among all raters, ranging from .707 to .999. Conclusion and Discussion. Our findings support the conclusion that under carefully controlled conditions, a 3-D motion measurement system can produce clinically acceptable measurements of accuracy across a range of angular speeds. Furthermore, acceptable accuracy is possible regardless of the digitization method.

Key Words: Accuracy • Digitization • Kinematics • Videotape analysis


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
ptjournalHome page
R. Dickstein, A. Dunsky, and E. Marcovitz
Motor Imagery for Gait Rehabilitation in Post-Stroke Hemiparesis
Physical Therapy, December 1, 2004; 84(12): 1167 - 1177.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Physical Therapy Association.