|
|
||||||||
Research Reports |
PC LaStayo, PT, CHT, is Instructor, Department of Physical Therapy, College of Health Related Professions, University of Florida, JHMHC Box 100154, Gainesville, FL 32610 (USA).
DL Wheeler, PhD, is Research Assistant, Department of Orthopaedics, University of Florida.
Background and Purpose. The purpose of this study was twofold: (1) to determine whether passive wrist flexion and extension goniometric measurements using ulnar alignment, radial alignment, and volar/dorsal alignment were similar or dissimilar and (2) to examine which of these three techniques had the greatest intratester and intertester reliability. Subjects. One hundred forty patients (141 wrists) were measured. The testers were 32 therapists from eight different hand/upper-extremity clinical sites around the United States. Methods. Randomly paired testers measured passive wrist flexion and extension. The intraclass correlation coefficient (ICC) was used as an estimate of agreement for both intratherapist (model 3,1) and intertherapist (model 2,1) reliability. Results. Six of the eight clinics showed significant differences among the various goniometric techniques. Flexion intratherapist mean ICCs for the radial, ulnar, and dorsal alignment techniques were .86, .87, and .92, respectively. Extension intratherapist mean ICCs were .80, .80, and .84 for the three techniques. Intertherapist flexion mean ICCs were .88, .89, and .93 for the radial, ulnar, and volar alignment techniques, respectively. Extension intertherapist mean ICCs were .80, .80, and .84 for the three techniques. The standard error of measurement was also used to quantify reliability, with the volar/dorsal alignment technique consistently producing less error than the ulnar and radial alignment techniques. The generalizability theory statistical model was utilized to identify the sources of error. The patient contributed to variance the most, although inherent error within the study, diagnostic category, therapeutic approach, and goniometric technique also contributed. Conclusion and Discussion. The overall results indicated there were differences among the three goniometric techniques. The volar/dorsal alignment technique is the goniometric technique of choice, as it consistently had the greatest reliability.
Key Words: Goniometry Tests and measurements, range of motion Upper extremity Wrist
Related Articles
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
Physical Therapy 1994 74: 684-685.
Physical Therapy 1994 74: 174-175.
Physical Therapy 1994 74: 175-176.
This article has been cited by other articles:
![]() |
R. R. BINDRA, J. J. DIAS, C. HERAS-PALAU, P. C. AMADIO, K. C. CHUNG, and F. D. BURKE Assessing Outcome after Hand Surgery: the Current State J Hand Surg Eur Vol., August 1, 2003; 28(4): 289 - 294. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Ellis and A. Bruton A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand Clinical Rehabilitation, May 1, 2002; 16(5): 562 - 570. [Abstract] [PDF] |
||||
![]() |
J. C. MACDERMID, E. FOX, R. S. RICHARDS, and J. H. ROTH Validity of Pulp-to-Palm Distance as a Measure of Finger Flexion J Hand Surg Eur Vol., October 1, 2001; 26(5): 432 - 435. [Abstract] [PDF] |
||||
![]() |
L. N Russek Examination and Treatment of a Patient With Hypermobility Syndrome Physical Therapy, April 1, 2000; 80(4): 386 - 398. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Geertzen, P. U Dijkstra, R. E Stewart, J. W Groothoff, H. J. T. Duis, and W. H Eisma Variation in measurements of range of motion: a study in reflex sympathetic dystrophy patients Clinical Rehabilitation, March 1, 1998; 12(3): 254 - 264. [Abstract] [PDF] |
||||
![]() |
B. Ellis, A. Bruton, and J. R Goddard Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand Clinical Rehabilitation, November 1, 1997; 11(4): 314 - 320. [Abstract] [PDF] |
||||
![]() |
A. Pandyan, M. Granat, and D. Stott Effects of electrical stimulation on flexion contractures in the hemiplegic wrist Clinical Rehabilitation, May 1, 1997; 11(2): 123 - 130. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |