PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 69, No. 9, September 1989, pp. 762-767

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hayes, K. W
Right arrow Articles by Sullivan, J. E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hayes, K. W
Right arrow Articles by Sullivan, J. E
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Articles

Reliability of a New Device Used to Measure Shoulder Subluxation

Karen W Hayes and Jane E Sullivan

K Hayes, MA, PT, is Assistant Professor, Programs in Physical Therapy, Northwestern University Medical School, 345 E Superior St, Rm 1323, Chicago, IL 60611 (USA).
J Sullivan, MS, PT, is Instructor in Clinical Physical Therapy, Programs in Physical Therapy, Northwestern University Medical School. She was Assistant Director, Physical Therapy Department, Rehabilitation Institute of Chicago, 345 E Superior St, 12th Floor, Chicago, IL 60611, when this study was conducted.

The purposes of the study were to determine the reliability of a new device used to quantify shoulder subluxation and to estimate its standard error of measurement. The device is an L-shaped thermoplastic jig with a metric tape measure embedded in it. A sliding beak-like marker, which can be anchored with a thumbscrew, is used to identify landmarks and to measure the amount of subluxation. Eight male and two female hemiplegic subjects, 40 to 80 years old, consented to be measured for subluxation. Three standardized subluxation measurements were taken by one investigator to determine the reliability with a single rater. One measurement was taken by a second investigator and compared with the first measurement obtained by the first investigator to determine the reliability using more than one rater. Both investigators were experienced physical therapists. Each measurement was read by the other investigator, who disassembled the jig and cleaned the marks from the patient between measurements. For both analyses, an analysis of variance for repeated measures reflected no differences between measurements attributable to raters. The unbiased intraclass correlation coefficent for a single measurement by a single rater was .89 (p < 01) and for more than one rater was .74 (p < .01). The standard error of measurement was ± 0.77 mm for a single rater and ± 1.20 mm for more than one rater. We recommend the jig as a tool to measure shoulder subluxation in patients.

Key Words: Hemiplegia, evaluation • Tests and measurements, general • Upper extremity, shoulder


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Neurorehabil Neural RepairHome page
I. A. K. Snels, H. Beckerman, J. J. ten Kate, G. J. Lankhorst, and L. M. Bouter
Measuring Subluxation of the Hemiplegic Shoulder: Reliability of a Method
Neurorehabil Neural Repair, September 1, 2001; 15(3): 249 - 254.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Physical Therapy Association.