PTJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


PHYS THER
Vol. 64, No. 12, December 1984, pp. 1831-1838

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Rapid Responses are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gronley, J. K
Right arrow Articles by Perry, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gronley, J. K
Right arrow Articles by Perry, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Special Issue: Biomechanics

Gait Analysis Techniques: Rancho Los Amigos Hospital Gait Laboratory

JoAnne K Gronley and Jacquelin Perry

Ms. Gronley is Research Coordinator and Research Physical Therapist, Pathokinesiology Service, Rancho Los Amigos Hospital, 7601 E Imperial Hwy, Downey, CA 90242 (USA).
Dr. Perry is Director, Pathokinesiology Service, Rancho Los Amigos Hospital, and Professor of Orthopaedic Surgery, University of Southern California, Los Angeles, CA.

In the gait laboratory at Rancho Los Amigos Hospital, the emphasis is on patient testing to identify functional problems and determine the effectiveness of treatment programs. Footswitch stride analysis, dynamic EMG, energy-cost measurements, force plate, and instrumented motion analysis are the techniques most often used. Stride data define the temporal and distance factors of gait. We use this information to classify the patient's ability to walk and measure response to treatment programs. Inappropriate muscle action in the patient disabled by an upper motor neuron lesion is identified with dynamic EMG. Intramuscular wire electrodes are used to differentiate the action of adjacent muscles. We use the information to localize the source of abnormal function so that selection of treatment procedures is more precise. Force and motion data aid in determining the functional requirement and the muscular response necessary to meet the demand. Determining the optimum mode of locomotion and developing criteria for program planning have become more realistic with the aid of energy-cost measurements. Microprocessors and personal computer systems have made compact and reliable single-concept instrumentation available for basic gait analysis in the standard clinical environment at a modest cost. The more elaborate composite systems, however, still require custom instrumentation and engineering support.

Key Words: Biomechanics • Electrodiagnosis • Gait • Laboratories


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Neurorehabil Neural RepairHome page
U. Stanic, R. Acimovic-Janezic, N. Gros, M. Kljajic, M. Malezic, U. Bogataj, and J. Rozman
Functional Electrical Stimulation in Lower Extremity Orthoses in Hemiplegia
Neurorehabil Neural Repair, January 1, 1991; 5(1-2): 23 - 36.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Physical Therapy Association.